HX Solutions Sdn. Bhd.
Internal Quality Audit Checklist
12 Aug 2025
| No. | Audit Criteria | Auditor | PIC | Auditee | Observations | Supporting Documents |
| 1 | Risks & Opportunities Assessment (Departmental) | Philip | T&C | Oon CH |
OK |
ROAF T&C |
| Philip | PD | Ho CH | OK | ROAF PD | ||
| Philip | ENG | Ho CH | OK | ROAF ENG | ||
| Philip | HRE | Evelyn Tan | OK | ROAF HRE | ||
| Philip | ADE | Evelyn Tan | ROAF 2025 ADM - None | |||
| Philip | PURE | Evelyn Tan | OK | ROAF PUR | ||
| Philip | Maint | Ho CH | OK | ROAF Maint | ||
| 2 | Quotation Log & Success Rate | Philip | T&C | Oon CH | Success Rate 67.0% | Quotation Analysis 2025 |
| 3 | Tender Log & Success Rate | Philip | T&C | Oon CH | Success Rate 12.5% | Tender Analysis 2025 |
| 4 | Business Loss Analysis | Philip | T&C | Oon CH | OK | Business Loss Analysis 2025 |
| 5 | Customer Satisfaction Survey Responses | Philip | QSA | Evelyn Tan | Done | CSS 2025 Responses |
| 6 | Customer Satisfaction Survey Chart Report | Philip | QSA | Evelyn Tan |
The Customer Satisfaction Survey Assessment
Chart 2025 was not raised as per procedure QSA-PRO-02. (Clause 9.1.2) |
|
| 7 | Customer Satisfaction Survey Follow Up Action | Philip | QSA | Evelyn Tan | Done | CSS Follow Up Action Report |
| 8 | Customer Inquiry & Complaints (CCF) | Philip | QSA | Evelyn Tan | One CCF - Closed | Vishay_Complaints_28Jun2025 |
| 9 | Drawing Tracking List / Drawing Log | Philip | ENG | Ho CH |
There were no evidence on the use of the
Drawing Log for the control of 3 shop drawings drawn by the
draughtswomen i.e. PKVCE 2503/E-2A, PKVCE 2503/E-3A and PKVCE
2314/E-2 for COHU project. (Clause 8.3.5) |
|
| 10 | Drafting Services - Shop Drawings | Philip | ENG | Ho CH |
There was no evidence of proper identification
of each set of shop drawings which was hung on the drawing rack
which will make traceability difficult. (Clause 8.5.2) |
|
| 11 | Design Plan Checklist | Philip | ENG | Ho CH | No Design and build project | |
| 12 | Design Input Plan | Philip | ENG | Ho CH | No Design and build project | |
| 13 | Measuring Tools & Calibration | Philip | PUR | Evelyn Tan | OK | Master Calibration List 2025 |
| 14 | Project Reference List | Philip | PD | Ho CH | OK | Current Projects 2025 |
| 15 | Project Quality Plan | Philip | PD | Ho CH |
There were an incident of stop work at ATX
project for one month on early 2025 due to owner/main contractor
issues and there was no evidence that the Company (HX Solutions)
being the subcontractor had put forward their EOT claims to the main
contractor. (Clause 8.1 and 8.5.1) |
|
| 16 | Maintenance Job - Gantt Chart | Philip | PD | Ho CH | OK | |
| 17 | Project Progress Meeting | Philip | PD | Ho CH | OK | |
| 18 | Project Log | Philip | PD | Oon CH | OK | |
| 19 | Project Insurance Cover | Philip | PD | Ho CH | OK | |
| 20 | Project Equipment Testing | Philip | PD | Ho CH | OK | |
| 21 | Material Approval | Philip | PD | Ho CH | OK - Vishay Maintenance Works | |
| 22 | Submittal Approval Form | Philip | PD | Ho CH | OK | |
| 23 | Project Punch / Defect List | Philip | PD | Ho CH | OK | |
| 24 | Purchase Order List (for Project Reference) | Philip | PURE | Evelyn Tan | OK | |
| 25 | Vendor Registration & Approval Form | Philip | PURE | Evelyn Tan | OK | |
| 26 | Approved Vendor List (Suppliers & Subcon) | Philip | PURE | Evelyn Tan |
(1) Only 32 out of a total of 38 active
suppliers had been evaluated on their annual performance as per the
vendor evalaution report 2025 and procedure CD-PRO-03 Vendor Control
Procedure. (2) The new subcontractor, Arrowlogic Sdn. Bhd. had been approved as the Registered Vendor but was not listed in the Approval Vendor List (Subcontractor). (3) Two new suppliers, Byteering Sdn. Bhd. and Asia Ducting Sdn. Bhd. had been listed in the Approval Vendor List (Suppliers) on Jan 2025, however, their vendor registration form was not available for audit. (Clause 8.4) |
Approved Supplier List 2025 |
| Approved Subcon List 2025 | ||||||
| 27 | Vendor Performance Evaluation Form | Philip | PURE | Evelyn Tan | Format error - need to re-do | Evaluation Forms 2025 |
| 28 | Vendor Performance Evaluation Report | Philip | PURE | Evelyn Tan | Format error - need to re-do | Evaluation Report 2025 |
| 29 | Purchase Requisition (PR) Log | Philip | PURE | Evelyn Tan | OK | |
| 30 | Purchase Order & Goods Received Notes | Philip | PURE | Evelyn Tan | OK | |
| 31 | Organization Chart - Update | Philip | HRE | Evelyn Tan | Updated 07 Apr 2025 | HX Org Chart |
| 32 | List of new employees | Philip | HRE | Evelyn Tan | OK | |
| 33 | Employee Induction Checklist | Philip | HRE | Evelyn Tan | OK | |
| 34 | Employee Job Descriptions | Philip | HRE | Evelyn Tan | OK - 3 new employees | |
| 35 | Employee CIDB Green Card | Philip | HRE | Evelyn Tan |
A recent recruited new Project Engineer (En.
Muhammad Adib Bin Azmi) were found to hold an expired CIDB Green
Card (Site Competency Card) and allowed to enter the poject sites. (Clause 7.2) |
|
| 36 | Employee Competency Report | Philip | HRE | Evelyn Tan |
The Employee Competency Report for year 2025
was raised for assessing the training requirement, however, the
following 5 employees as per the Company's organization chart dated
7/4/2025) were left out of the said report: (1) Muhammad Ikhwan (Chargeman/PW4). (2) Liyu Kim Choy (Wiring Supervisor). (3) Ang Kong Pin (Wiring Supervisor). (4) Khoo Teck Soon (Wiring Supervisor). (5) Ow Chee Loy (Wiring Supervisor). (Clause 7.2) |
Employee Competency Report 2025 |
| 37 | Annual Training Plan | Philip | HRE | Evelyn Tan | OK | Annual Training Plan 2025 |
| 38 | Attendance List (For Record Training) | Philip | HRE | Evelyn Tan | OK | |
| 39 | Training Evaluation Form | Philip | HRE | Evelyn Tan | OK | |
| 40 | Employee Training Record | Philip | HRE | Evelyn Tan | OK | |
| 41 | Preventive Maintenance for Office Equipment | Philip | ADE | Evelyn Tan | OK | |
| 42 | Office Rental | Philip | ADE | Evelyn Tan | Not Applicable | |
| 43 | Internal Quality Audit Plan | Philip | QMA | Philip | OK | 2025 IQA Plan |
| 44 | Internal Quality Audit Checklist | Philip | QMA | Philip | OK | 2025 IQA Checklist |
| 45 | Internal Quality Audit Report | QMA | Philip | OK | 2025 IQA Report | |
| 46 | Organizational Knowledge Monitoring Chart | Philip | IM | Evelyn Tan | OK | Annex K |
| 47 | Internal Communications Meeting - Minutes | Philip | IM | Evelyn Tan |
There were
no evidence of conducting the internal communication meeting for
year 2024 and 2025 to meet the Company's Quality Objective No. 3 to
create communications among the top management with the lower level
staff. (Clause 7.4) |
|
| 48 | External & Internal Issues - Update | Philip | IM | Evelyn Tan | OK | Annex B (1) |
| 49 | Needs & Expectation of Interested Parties | Philip | IM | Evelyn Tan | OK | Annex B (2) |
| 50 | Quality Objectives Achievement | Philip | IM | Evelyn Tan | OK | Annex H |
| 51 | Corrective & Preventive Actions (NCR) | Philip | IM | Evelyn Tan | None | |
| 52 | Analysis of Data | Philip | IM | Evelyn Tan | OK | Annex O |
| 53 | Management Review Meeting | Philip | IM | Evelyn Tan | OK | |
| 54 | BV Surv Audit 1 Audit Plan | Philip | IM | Evelyn Tan | OK | 27-Aug-2025 (Plan) |
| 55 | BV Surv Audit 1 Audit Report | Philip | IM | Evelyn Tan | OK | |
| 56 | Company Outing / Events | Philip | ADE | Evelyn Tan | Sui Kang Chiew & Hari Raya Puasa Gathering 2025 | 2 Events |
| 57 | Awareness of Quality Policy & Quality Objectives | Philip | IM | Evelyn Tan |
Two old posters on Quality Policy and Quality
Objectives needs to be updated and to be properly signed by the MD
for display at Main Office. (Clause 5.2.2 and 7.3) |
|
| 58 | Archive of Documents | Philip | ADE | Evelyn Tan |
There were a number of boxes containing past
documents (particularly accounts related) for retention located at
the Archive Rack which does not have any archive labels for
identification and traceability. (Clause 7.5.3 and 8.5.2) |
|
| Audited by | ||||||
| (1) Lead Auditor: Philip Yong | ||||||
| Date: 12 Aug 2025 | ||||||
>>> Sitemap